Home >> UPS Battery  

UPS Battery

Product Name:maintenance free batteries
Title:battery
Specifications:
Overview:
NP, GM-Series VRLA maintenance free batteries, combined with high standards military use maintenance-free lead-acid battery manufacturing technology, used high quality lead as the main raw material, introduced Germany's sunny production technology, the products have good stability, reliability and long service life.

Description

            NP, GM-Series VRLA maintenance free batteries, combined with high standards military use maintenance-free lead-acid battery manufacturing technology, used high quality lead as the main raw material, introduced Germany's sunny production technology, the products have good stability, reliability and long service life.

Application
Widely used in aerospace equipment, financial systems data centers, telecommunications mobile computer network center backup power supply, backup power for unattended base station, solar photovoltaic systems, military power, back up power for medical equipment and other important areas.
Technical merits:
●Good airtight performance, no leakage and no acid pollution
●No water loss, no need to add electrolyte
●Special grid design, have excellent discharge performance
●Low impedance and self-discharge, capacity to maintain and storage time can be up to above 12 months at below 20℃.
●C.C.D.S charging and discharging test system to ensure product consistency
●Use high strength engineering plastic as raw material and high-density ultra-fine glass fiber separator, creating top quality batteries
Charging method:
Sealed lead-acid battery capacity and life is governed by the charging voltage, ambient temperature and other parameters, so one important principle for using such kind battery is adopting right charging method. The charging methods depends on the battery running status, usually have two status, are CYCLICUSE (as main power) and FLOATUSE ( as back up power), the following table describes the corresponding charging methods (C for the battery rated capacity)

Application 

Charging methods

Cyclic use

Float use

      

 

Constant voltage charging

Charging voltage range

Charging voltage range

12V battery:14.514.9V

12V battery:13.613.8V

2V battery:2.352.45V

2V battery:2.232.38V

Initial current (A):≤0.3C,best 0.1C

Initial current (A):≤0.3C,best 0.1C


On the table, the charging voltage is under condition of the 25 ℃ ambient temperature, when the temperature changed greatly, the charging voltage should be adjusted accordingly, the method is:
●Charging voltage reduce 0.003V/cell when ambient temperature rise every 1℃
●Charging voltage rise 0.003V/cell when ambient temperature reduce every 1℃
●If ambient temperature changes more than 10℃, without amendment float charging voltage, may cause the battery damage, it is best to use the battery in the range of 20 ~ 25 ℃ in air-conditioned room.

Recovery charge
In the following circumstances, in need of recovery charge:
● The battery installed but before using
● After the battery discharge
● Battery storage for more than six months;
● Single-cell battery float charging voltage lower than 2.20V, should increase its float charging voltage in short-time; recovery charge voltage 2.30 ~ 2.35V / single cell, the best 2.35V / single cell, recovery charge time 8 to 10 hours (ambient temperature 21 ~ 32 ℃) or 12 to 16 hours (ambient temperature 10 ~ 19 ℃)
If found single-cell battery float charging voltage is very low, it is may caused by the following reasons and deal with as the followings:
●charging voltage is lower than normal to re-adjust the float charging voltage.
●terminals or connecting strips don’t combine close should re-connect.
●load changes frequently and largely, the charger can not automatically adjust in time, can increase float charging voltage 0.02 ~ 0.03V / single cell.

Matters need attention:
● Keep away from heat
● When handling the battery, you must use insulated tools to prevent short circuit.
● The force to tighten the nuts should be uniform not too large, to avoid the damage the pole column, leakage occurs. Different types models and old new batteries can’t use together
Main technical parameters:
GM-2V series VRLA maintenance free battery

Model

Voltage

(V)

Capacity(AH)

Internal resistance(mΩ)

Weight(Kg)

Sizemm

Length

Width

Height

Total length

GM200

2

200

≤0.7

18

172

107

346

380

GM300

2

300

≤0.65

23

172

150

346

380

GM400

2

400

≤0.5

30

220

172

353

400

GM500

2

500

≤0.4

38

240

172

353

400

GM800

2

800

≤0.24

65

410

172

353

400

GM1000

2

1000

≤0.2

76

480

172

353

400

GM2000

2

2000

≤0.12

150

490

350

368

400

GM3000

2

3000

≤0.11

225

710

350

368

400

NP-12V-Series VRLA maintenance free batteries

Model

Voltage(V)

Capacity

(AH)

Internal resistance

(mΩ)

Weight

(Kg)

Sizemm

Length

Width

Height

Total length

NP-12V4AH

12

4

≤40

1.7

91

70

101

108

NP-12V7AH

12

7

≤22

2.3

151

65

94

101

NP-12V12AH

12

12

≤17

4

151

99

94

101

NP-12V17AH

12

17

≤16

8.5

180

77

167

167

NP-12V24AH

12

24

≤8.3

9

165

125

175

180

NP-12V38AH

12

38

≤7.3

14.5

197

165

175

180

NP-12V65AH

12

65

≤6.1

22

350

166

175

175

NP-12V100AH

12

100

≤4.4

33

407

173

210

236

NP-12V150AH

12

150

≤3.5

42

483

170

239

240

NP-12V200AH

12

200

≤3.4

55

522

240

219

244