Home >> Low Frequency Online UPS
KSD-series small and medium power three phase input single phase output UPS, single unit capacity from 6KVA to 60KVA. This series products adopt advanced digital design, the perfect combination of high-speed digital chips, ASIC's DDC control technology, advanced high-power IGBT and SCR devices, are large capacity, high reliability and superior performance intelligent UPS. This series product is the latest international hardware and the most advanced software combination.
Application:
To provide reliable power protection for the centralized server room, network management center and computer center.
Technical merits:
●Top technology application:
DDC (Direct Digital Control) / DSP (Digital Signal Processor) ASIC (Application Specified IC) IC/CPU (microprocessor)
●100% digital technology
Adopting high-speed micro-controller to achieve circuit control, parameter setting, the program running management, and advanced self-test and self-detection feature, which allows self-test and failure analysis to all the independent circuit connections on the circuit board . The sine wave voltage getting through digital transformation and new perfect running programs can meet your actual needs
●IGBT(Insulated Gate Bipolar Transistor)excellent performance:
Good high speed switches high voltage and large current working characteristics; adopt voltage- driven, only need small control power; working with high efficiency (low loss and low heat value), drive circuit miniaturization and high reliability.
● Fully meet the load jump from 0 to 100%:
The ability to provide instant full load requirements, but do not need to switch to bypass and keep output stable and reliable
● Large screen LCD monitor for convenient operation:
Running status, operational procedures, measurements value, troubleshooting information, image information, etc., are clear at a glance through the menu operation.
●Complete protection function:
With a variety of system protections, have protection alarm function to super-voltage, low voltage, over current, overload, short circuit, waveform distortion.
●Instantaneous waveform control method used to achieve the small output voltage distortion:
Current local loop control, the inverter adapt to the impact current when load starts up, and can high-speed control over-current caused by surge, UPS can get rapid response to the load changes .
●Convenient communication:
RS232 communication port can truly realize multi-purpose communication and remote monitoring
●Intelligent battery management function:
UPS can set the battery charging current through internal software, automatically charge and discharge battery once every three months, at the same time carrying out 30mins average charging to the battery, so the battery maintain automatically, don’t need man operation, can prolong battery service life.
Technical parameters: Model KSD-6KVA KSD-8KVA KSD-10KVA KSD-15KVA KSD-20KVA Rated capacity 6KVA 8KVA 10KVA 15KVA 20KVA Input Voltage range 380VAC±25﹪(285VAC~475VAC) Frequency range 50/60Hz±5﹪ Phase Three phase +N+G Output Waveform Pure sine wave Voltage 220VAC±1﹪ Frequency 50/60Hz±0.05%(battery mode) Waveform distortion Linear load< 2%, non linear load< 5% Power factor ≥0.8 battery Battery type Maintenance lead acid battery Dc voltage 192VDC Cut-off voltage 164±1VDC Float charging voltage 220VDC System Controlling mode Adopting SPWM pulse width modulation technology Overload capacity overload125% maintain 5min to bypass, overload 150% maintain 1S to bypass ransfer time 0ms Efficiency >95﹪ Man-machine interface LCDdisplay Input/output voltage and frequency, battery voltage, load power factor, internal temperature, running status LEDindicator Mains power, inverted, battery、bypass, overload, abnormal RS232 communication interface Connect to computer software: monitoring UPS running status、schedule power on/off UPS、power status analysis、automatically archive history record Remote monitoring management Optional SNMP remote monitoring card, remote monitoring UPS running status, schedule power on/off UPS, automatically archive history record, send message alarm Protection Surge protection In line with IEEE527 standards Noise protection In line with FCC A standards Ambient Noise < 56dB( Operating temperature 0~40℃ Relative humidity 20﹪~90﹪(non-condensing) Operating height Altitude < UPSnet weight 168 Kg 185 Kg 200 Kg 258Kg 350Kg Size( W*D*H) mm 800×300×590 675×410×835 730×460×1100
|
Model |
KSD-30KVA |
KSD-40KVA |
KSD-50KVA |
KSD-60KVA |
||
|
Rated capacity |
30KVA |
40KVA |
50KVA |
60KVA |
||
|
Input |
Voltage range |
380VAC±25﹪(285VAC~475VAC) |
||||
|
Frequency range |
50/60Hz±5﹪ |
|||||
|
Phase |
Three phase+N+G |
|||||
|
Output |
Waveform |
Pure sine wave |
||||
|
Voltage |
220VAC±1﹪ |
|||||
|
Frequency |
50/60Hz±0.05﹪(battery mode) |
|||||
|
Waveform distortion |
Linear load< 2%, non linear load< 5% |
|||||
|
Power factor |
≥0.8 |
|||||
|
battery |
Battery type |
Maintenance lead acid battery |
||||
|
Dc voltage |
240VDC |
360VDC |
||||
|
Cut-off voltage |
204±1VDC |
306±1VDC |
||||
|
Float charging voltage |
275VDC |
412 VDC |
||||
|
System |
Controlling mode |
Adopting SPWM pulse width modulation technology |
||||
|
Overload capacity |
overload125% maintain 5min to bypass, overload 150% maintain 1S to bypass |
|||||
|
Transfer time |
0ms |
|||||
|
Efficiency |
>95﹪ |
|||||
|
Man-machine interface |
LCD display |
Input/output voltage and frequency, battery voltage, load power factor, internal temperature, running status |
||||
|
LED indicator |
Mains power, inverted, battery、bypass, overload, abnormal |
|||||
|
RS232 communication interface |
Connect to computer software: monitoring UPS running status、schedule power on/off UPS、power status analysis、automatically archive history record |
|||||
|
Remote monitoring management |
Optional SNMP remote monitoring card, remote monitoring UPS running status, schedule power on/off UPS, automatically archive history record, send message alarm |
|||||
|
Protection |
Surge protection |
In line with IEEE527 standards |
||||
|
Noise protection |
In line with FCC A standards |
|||||
|
Ambient |
Noise |
<56dB(1m away from UPS) |
||||
|
Operating temperature |
0~40℃ |
|||||
|
Relative humidity |
20﹪~90﹪(non-condensing) |
|||||
|
Operating height |
Altitude < |
|||||
|
UPS net weight |
400 Kg |
440 Kg |
520Kg |
560 Kg |
||
|
Size( W*D*H) mm |
730×460×1100 |
730×720×1450 |
||||