Home >> Low Frequency Online UPS  

Low Frequency Online UPS

Product Name:KSS-series 3-3 online UPS
Title:KSS-series three phase low frequency online UPS
Specifications:6KVA 10KVA 15KVA 20KVA 30KVA 40KVA
Overview:
KSS-series three phase low frequency online UPS, to meet the demand for high and medium power UPS, is researched and well designed UPS by the company's technology R & D center, organized dozens of professional and technical engineering staff, combining international cutting-edge three phase low frequency online UPS. This series UPS use advanced digital design, high-speed 16 digital chips, ASIC’s DDC control technology, advanced IGBT power device and SCR, is big capacity, high stability and reliability and excellent performance intelligent UPS.

Description

     KSS-series three phase low frequency online UPS, to meet the demand for high and medium power UPS, is researched and well designed UPS by the company's technology R & D center, organized dozens of professional and technical engineering staff, combining international cutting-edge three phase low frequency online UPS. This series UPS use advanced digital design, high-speed 16 digital chips, ASIC’s DDC control technology, advanced IGBT power device and SCR, is big capacity, high stability and reliability and excellent performance intelligent UPS.
Application
This series three phase low frequency online UPS widely used in information center server room of important areas, large microcomputer-controlled automated production equipment, large precision medical equipment and precision electric control equipment.
Main technical merits:
● Adopting international advanced IGBT module excellent performance
    Good high speed switches high voltage and large current working characteristics; adopt voltage-    driven, only need small control power; working with high efficiency (low loss and low heat value), drive circuit miniaturization and high reliability.
● Application of international cutting-edge technology
    DDC(Direct Digital Control) /DSP(Digital Signal Processor)/ASIC(Application Specified IC)/CPU     (microprocessor)。
100% digital technology
Adopting three pieces high-speed micro-controller to achieve circuit control, parameter setting, the program running management, and advanced self-test and self-detection feature, which allows self-test and failure analysis to all the independent circuit connections on the circuit board . The sine wave voltage getting through digital transformation and new perfect running programs can meet your actual needs
●Fully meet the load jump from 0 to 100%:
In some cases, UPS must have the ability to provide instant full load, practice has proved that KSS series intelligent low frequency online UPS can fully meet this requirement, and do not need to switch to bypass and keep output stable and reliable
●Instantaneous waveform control method used to achieve the small output voltage distortion:
Three-phase independent transient wave control, achieving control transient overload degree of overload; current local loop control, the inverter adapt to the impact current when load starts up, and can high-speed control over-current caused by surge, feed forward control can make UPS get rapid response to the load changes .
● Highly secure and reliable design, complete protection function
With a variety of system protection, have protection alarm function to over voltage, lack voltage, over current, over load, short circuit and waveform distortion, so the machine failure rate is very low.
● Allow three phase 100% unbalance working
This series UPS adopts three phase independent modulation and full-bridge inverter technology, UPS can work normally when three phase load 100% unbalance, the technology is international advanced.
● Improved intelligent functions
Through RS232 communication interface computer can realize UPS monitoring and management function, including AC power status and monitoring, recording, analyzing UPS working status, schedule power on/off UPS, monitoring UPS itself testing management, power interruption alarm, automatic power off system safely in very low battery status, send messages to users by mobile phone or email.
● Equipping SNMP adapter through RS232 communication interface through, constituting network remote management system to realize remote centralized monitoring and management, management software supports operating systems: Novell, Netwer, MS-windows95, MS-windows98, MS-windows2000, MS-windowsNT, MS- windowsXP, FreeBSD, Unix, Linux, etc.
●Big screen LCD monitoring operation interface
UPS with LED and LCD dual display system, when UPS works abnormally caused by the abnormal city power or city power failure ,UPS internal microcomputer CPU will display system fault state through the LED and LCD Dual display system, so that the user or technical managers can learn abnormal causes accurately in order to make the right deal timely.

 

Main technical parameters:
Three phase low frequency online UPS6KVA-60KVA

 

Model
KSS-6KVA
KSS-10KVA
KSS-15KVA
KSS-20KVA
KSS-30KVA
KSS-40KVA
KSS-50KVA
KSS-60KVA
Rated capacity
6KVA
10KVA
15KVA
20KVA
30KVA
40KVA
50KVA
60KVA
 
AC input
Phase
Three phase +N+G
Voltage
380V±25%
Frequency
50Hz/60Hz±10%
Soft start
0~100% 5sec
 
AC output
Phase
Three phase +N+G
Voltage
380V±1%(fixed stable load), 380V±3%(load fluctuation)
Frequency
50Hz/60Hz±0.05(battery mode)
Waveform
Sine wave
Harmonic distortion
Linear load 2%,nonlinear load < 4%
Power factor
≥0.8
 
System
Transfer time
0ms
Control mode
SPWM pulse width modulation technology
Efficiency
95%
Overload capacity
Overload 120%maintain 10min to bypassoverload 150% maintain 1 S to bypass
 
Battery
Battery type
Maintenance free lead acid battery
DC voltage
360VDC
Cut-off voltage
315±1VDC
Float charging voltage
405VDC
Cooling mode
RS232 communication interface
Connect to computer software: monitoring UPS running status, schedule power on/off UPS, power status analysis, automatically archive history record
Remote monitoring management
Optional SNMP remote monitoring card, remote monitoring UPS running status, schedule power on/off UPS, automatically archive history record, send message alarm
 
Ambient
Running temperature
0~45
Relative humidity
30%~90%
Running height
2000m (power reduce 1% every 1000m heighten, the most can be 4000m)
Noise (dB)
48~60(1m away from UPS)
53~65(1m away from UPS)
Size ( W*D*H) mm
720×450×1035
600×700×1350
710×850×1500
UPS weight (kg)
180
215
260
335
410
490
585
660

 
Three phase low frequency online UPS80KVA-300KVA

Model
KSS-80KVA
KSS-100KVA
KSS-120KVA
KSS-140KVA
KSS-160KVA
KSS-200KVA
KSS-300KVA
Rated capacity
80KVA
100KVA
120KVA
140KVA
160KVA
200KVA
300KVA
 
AC input
Phase
Three phase +N+G
Voltage
380V±25%
Frequency
50Hz/60Hz±10%
Soft start
0~100% 5sec
 
AC output
Phase
Three phase +N+G
Voltage
380V±1% (fixed stable load ),380V±3% (load fluctuation)
Frequency
50Hz/60Hz±0.05 (battery mode)
Waveform
Sine wave
Total harmonic distortion
Linear load < 2%,nonlinear load < 4%
Power factor
≥0.8
 
System
Transfer time
0ms
Control mode
SPWM pulse width modulation technology
Efficiency
 > 95﹪
Overload capacity
Overload 120%maintain 10minto bypass,overload 150%maintain 1S to bypass
 
Battery
Battery type
Maintenance free lead acid battery
DC voltage
360VDC
Cut-off voltage
315±1VDC
Float charging voltage
405VDC
Cooling mode
Forced ventilation (through the temperature control circuit)
RS232 communication interface
Connect to computer software: monitoring UPS running status, schedule power on/off UPS, power status analysis, automatically archive history record
Remote monitoring management
Optional SNMP remote monitoring card, remote monitoring UPS running status, schedule power on/off UPS, automatically archive history record, send message alarm
 
 
Ambient
Running temperature
0~45
Relative humidity
30%~90%
Running height
< 2000m (power reduce 1% every 1000m heighten, the most can be 4000m)
Noise (dB)
55~68 (1m away from UPS)
60~65 (1m away from UPS)
Size ( W*D*H) mm
110×860×1680
1500×1160×1800
1800×1250×1800
UPS weight (kg)
905
970
1100
1190
1400
1580
1900