Home >> Low Frequency Online UPS  

Low Frequency Online UPS

Product Name:KD-series 1-1 online UPS
Title:Single phase low frequency online UPS
Specifications:1KVA-30KVA
Overview:
KD-Series low frequency online UPS is a high quality well-designed intelligent low frequency online UPS for the safe protection of computer networks and sophisticated electronic equipment, electrical equipment at complex network environment. Adopting on line double conversion technology, zero interrupt conversion, can completely eliminate all kinds of network interference and failure in providing clean power for the load to ensure the load equipment run efficiently. AC / DC input with harmonic suppressors, so that UPS have no harmonic pollution to the electricity grid; DC / AC inverter uses international advanced SPWM pulse width modulation technology, IGBT power module and the output isolation transformer so that UPS can output stable pure sine wave power; while with ultra-wide input voltage range and voltage and frequency stabilization function, strong load capacity, can be compatible with the generator to meet the needs of the load equipment protection in complex grid environment.

Description

KD-Series low frequency online UPS is a high quality well-designed intelligent low frequency online UPSfor the safe protection of computer networks and sophisticated electronic equipment, electrical equipment at complex network environment. Adopting online double conversion technology, zero interrupt conversion, can completely eliminate all kinds of network interference and failure in providing clean power for the load to ensure the load equipment run efficiently. AC / DC input with harmonic suppressors, so that UPS have no harmonic pollution to the electricity grid; DC / AC inverter uses international advanced SPWM pulse width modulation technology, IGBT power module and the output isolation transformer so that UPS can output  stable pure sine wave power; while with ultra-wide input voltage range and voltage and frequency stabilization function,  strong load capacity, can be compatible with the generator etc. ,  to meet the needs of the load equipment protection in complex grid environment

Technical merits:

Adopting double conversion technology and the perfect static electronic bypass technology, realizing real zero     interrupt conversion, the user equipment can run reliably in any complex power grid environment.

●Intelligent digital control technology and improved protection, stability and reliability.

   All IGBT power devices using the imported famous brands, have greater impact resistance          and overload capacity.

●Advanced automatic constant voltage constant current charging technology and float charging technology to realize   the maximum activation of the battery

●Ultra wide input voltage and frequency stabilization range, greatly reduced the times of battery discharging, can    extend the battery service life.

●Has the perfect cold-start, in no electricity power state, batteries can be used directly to start UPS to provide   stable AC power for the user load to meet users’ emergency needs.

●Output precise synchronization phase with the network, to protect the safety and reliability of static electronic   bypass.

●Through RS232 communication interface computer can realize UPS monitoring and management function,     including AC power status and monitoring, recording, analyzing UPS working status, schedule power on/off UPS, monitoring UPS itself testing management, power interruption alarm, automatic power off system safely in very low battery status, send messages to users by mobile phone or email.

● Equipping SNMP adapter through RS232 communication interface through, constituting network remote management system to realize remote centralized monitoring and management, management software supports operating systems: Novell, Netwer, MS-windows95, MS-windows98, MS-windows2000, MS-windowsNT, MS- windowsXP, FreeBSD, Unix, Linux, etc.

●UPS with LED and LCD dual display system, when UPS works abnormally caused by the abnormal city power or city power failure ,UPS internal microcomputer CPU will display system fault state through the LED and LCD Dual display system, so that the user or technical managers can learn abnormal causes accurately in order to make the right deal timely.

●Ultra wide AC power input voltage and frequency range, can be compatible with any form AC power, including the adaptation of industrial power generation, wind power, etc.

LED and LCD dual displaying system, can clearly and accurately displaying UPS operating status, so man-machine communication zero distance, truly realize friendly man-machine interface.

Internal partition modular design with compact size, beautiful and elegant appearance, small footprint.

●Using advanced anti-electromagnetic interference technology, fully in line with international standards, has good electromagnetic compatibility, and maximizing eliminates load equipment electronic interference.

●Input and output electronic circuit with a harmonic filter, the maximum elimination harmonic interference caused by UPS to the network environment.

 Mains technical parameters:

Model
KD-1KVA
KD-2KVA
KD-3KVA
KD-4KVA
KD-5KVA
KD-6KVA
Rated capacity
1KVA
2KVA
3KVA
4KVA
5KVA
6KVA
Input
Voltage range
220VAC±25(165VAC275VAC)
Frequency range
50/60Hz±5
Phase
Single phase+N+G
Output
Waveform
Pure sine wave
Voltage
220VAC±1
Frequency
50/60Hz±0.05(battery power)
Waveform distortion
Linear load <2﹪,non linear load <5﹪
Power factor
0.8
Battery
Battery type
Maintenance free lead-acid battery
DC voltage
48VDC
192VDC
Cut-off voltage
41±1VDC
164±1VDC
Float charging voltag
55VDC
220VDC
System
Control mode
SPWM pulse width modulation technology
Overload capacity
Overload 125%maintain 5mins to bypass, overload 150%maintain 1S to bypass
Transfer time
0ms
Efficiency
95
Man-machine
interface
LCDdisplay
Input, output voltage and frequency, battery voltage, load power, internal temperature, working statusInput, output voltage and frequency, battery voltage, load power, internal temperature, working status
LEDndicator
Mains power, inverted, battery, bypass, overload, abnormal
RS232communication interface
Connected with computer software: monitoring UPS working status、schedule power on/off UPS、analyze power status、automatically archive history record
Remote monitoring
management
optional SNMP remote monitoring card, remote monitoring UPS working status, schedule power on/off UPS, automatically archive history record, send message alarm
Protection
Surge protection
In line with IEEE527 standards
Noise protection
In line with FCCA standards
Ambient
Noise
55dB(1m away to UPS)
Operating
temperature
040
Relative humidity
20﹪~90(no condensing)
Operating height
Altitude <2500m(capacity reduce 5% every 500m heighten)%)
UPS net weight
50Kg
65Kg
75Kg
62Kg
65 Kg
70 Kg
size( W*D*H) mm
410×200×535
480×200×600
650×23580

 

Model
KD-8KVA
KD-10KVA
KD-15KVA
KD-20KVA
KD-25KVA
KD-30KVA
Rated capacity
8KVA
10KVA
15KVA
20KVA
25KVA
30KVA
Input
Voltage range
220VAC±25% (165VAC275VAC)
Frequency range
50/60Hz±5%
Phase
Single phase +N+G
 
Output
 
Waveform
Pure sine wave
Voltage
220VAC±1%
Frequency
50/60Hz±0.05% (battery power)
Waveform distortion
Linear load< 2%,non linear load< 5%
Power factor
0.8
Battery
Battery type
Maintenance free lead-acid battery
DC voltage
192VDC
240VDC
Cut-off voltage
164±1VDC
204±1VDC
Float charging voltage
220VDC
275VDC
System
Control mode
SPWM pulse width modulation technology
Overload capacity
Overload 125% maintain 5mins to bypass, overload 150% maintain 1Sto bypass
Transfer time
0ms
Efficiency
> 95%
Man-machine
interface
LCD display
Input, output voltage and frequency, battery voltage, load power, internal temperature, working status
LED indicator
Mains power, inverted, battery, bypass, overload, abnormal
RS232communication interface
Connected with computer software: monitoring UPS working status, schedule power on/off UPS, analyze power status, automatically archive history record
Remote monitoring
management
Optional SNMP remote monitoring card, remote monitoring UPS working status, schedule power on/off UPS, automatically archive history record, send message alarm
Protection
Surge protection
In line with IEEE527 standards
Noise protection
In line with FCC A standards
Ambient
Noise
< 55dB(1m away to UPS)
Operating
temperature
040
Relative humidity
20%90% (non-condensing )
Operating height
Altitude < 2500m(capacity reduce 5% every 500m added)
UPS net weight
89 Kg
100 Kg
210 Kg
280 Kg
300 Kg
360 Kg
Size ( W*D*H) mm
800×300×590
730×410×835
730×460×1180